Floor-Mounted DR Machine Features
- Flexible system, exquisite and flexible UC-arm System, large movement range and angle, completely meet the needs of doctors
- Sharp detection, high sensitivity, full-size detector, intelligent control
- Precision ray, high-quality high-frequency X-ray generator, high production accuracy, high image quality, small volume
1. Flat Panel Detector
- Type of the detector: TFT monolithic amorphous silicon
- Panel size of the detector: 430mm*430mm
- Efficient imaging size of the detector: 17*17 inch
- Acquisition pixel matrix of the detector: ≥3072×3072
- The pixel pitch of the detector: ≤146 um
- The spatial resolution of the detector: 3.7LP/MM
- Pixel grayscale: 17-bit
- Time of image acquisition and transmission: 3s
2. High frequency and high voltage generator
- Max. Output power: 50kw
- Input power supply: 380 VAC three-phase
- Output voltage: 40~150kV
- Tube current range: 10~630mA
- Exposure time range: 1ms-10000ms
- mAs range: 0.1mAs~1000mAs
- Support AEC、APR automatic exposure
- Diagnostic self-test and display
3. X-ray bulb tube assembly
- Focus: 0.6mm/1.5mm
- Nominal electric power: 22kw/54kw (50Hz)
- Max. KV: 150kV
- Anode target angle: 12°
4. UC arm stand
- Bend arm rotation angle range (ROT): -30°~120°, deviation±2°
- Bend arm up-and-down motion (FID): 430~1700mm, deviation±20mm
- Bulb tube SID lateral movement range: 1000~1800mm, deviation±50mm
- Rotation angle range of the detector: -30°~+30°, deviation±2°
5. Moving bed
- The height distance between the bed surface and the ground is 690mm, deviation of ±50mm
- The length of the bed surface is 2000mm, width 630mm, deviation ±50mm
- The locking mode is mechanical locking. Breaking force≥100N
6. The grid and the beam-limiting device
- The grid material: Aluminum-based grid
- Size: 18×18 inch (48×48cm)
- Grid ratio: 10:1
- Wire/inch: 215C
- Grid Focal length: 1000mm
- Light field, multi-blade DR beam limiting device
7. Workstation functions for image acquisition, processing, and diagnosis
- The Chinese user interface, standard DICOM3.0 image
- Workstation functions for image acquisition: adjust or preset window width/ window level, local automatic window level, preset window width/ window level, positive and negative image flipping, image flipping, rotation, image magnification and roam, image interpolation edge enhancement, local magnification, restoration, image annotation, text annotation/number annotation, image marking, ruler line segment measurement, square and round measurement, arbitrary shape measurement, angle measurement, automatic electron sharing, image stitching, acquisition and display of exposure index
- Software package for the special image acquisition control and software package for special parts protocol processing
- Functions of patient management, image acquisition, image processing (image correction, image flipping, USM sharpening, image filtering), image observation (provide the tools for observation and measurement), image stitching
- Image printing, DICOM printing, paper printing, manual printing for the displayed images, a single button for marking and printing the images, optional for different printers, film format, and number of prints, print queue control, stop/start the preset
- User personalization: showing the format and layout, default setting, toolbar setting, and parts protocol enhancement filter
- Image display: display configuration 1920×1080, HD display
8. Workstation
- CPU: Intel i5,3GHz or above
- Host memory: ≥8GB DDR3 1600 high speed memory
- Hard disk: 1T/7200rpm large capacity and high-speed hard disk
- Workstation monitor: 24” IPS LCD monitor
- Network card and network interface: 1000M network card, 1000M network interface, Jumbo Frames: 9K
- DICOM3.0 interface
- Windows 10 64-bit SP1 (Professional Edition or higher)